NOVARYNINDUSTRIAL LIMITED

Combustion air cooling / engine performance

Charge Air Coolers

Charge air coolers for diesel and gas engines, improving combustion air density, engine efficiency, and operating stability.

Family
Engine cooling
Series
1
Core standards
ASME VIII Div. 1 · EN 13445
Document set
3 records
Charge Air Coolers — representative Novaryn equipment
Novaryn equipment referenceTX / US

Product overview

Novaryn charge air coolers are presented for OEM and plant-system work where airflow guidance, fin geometry, corrosion protection, and engine integration are central to performance.

Planning reference

Engine type
2-stroke and 4-stroke planning paths
Cooling path
Charge air to coolant
Integration
OEM module or plant-system route

Representative summary. Project duty, materials and certification are confirmed at selection.

Specification framework

Standards, materials and the conditions that shape the unit.

The framework below is common to this line. It is not a substitute for a project datasheet: the final pressure class, material schedule, connection detail and test regime are fixed against the duty point.

01

Design standards

  • ASME VIII Div. 1
  • EN 13445
  • ISO 15550
  • PED 2014/68/EU

02

Material scope

  • Carbon steel
  • Stainless steel
  • CuNi
  • Titanium
  • Aluminium

03

Selection inputs

  • Media and flow rate
  • Inlet / outlet temperature
  • Design pressure and temperature
  • Ambient and site conditions
  • Plot, weight and access constraints
  • Documentation and certification

Engineering intent

What this line is built to do.

01

Optimized fin geometry

02

Plug-and-play installation planning

03

Reduced fouling

04

High transfer surface contribution

Areas of application

Typical placements for this line. Final suitability is confirmed against the site conditions and the project specification.

Diesel and electric railMarine on-board systemsGreen hydrogen

Series & variants

1 series. Three planning sizes each.

Series entries define the configuration route. The tables are representative planning grids, not certified performance data. Project-specific ratings, dimensions and connections are issued on the datasheet.

NX-EC-062

Engine

OEM and replacement modules

OEM and replacement modulesGas and diesel enginesSpecial fuel support
ModelHeat loadFlow rateCircuitPart number
NX-EC-062-S50 kW8 m³/hSeawaterNX-EC-062-S
NX-EC-062-M100 kW16 m³/hCharge airNX-EC-062-M
NX-EC-062-L150 kW24 m³/hWater / glycolNX-EC-062-L

Representative planning grid · not for construction · certified data on project datasheet

General arrangement

Documentation

The line folder.

Datasheet, product overview and general arrangement are public. Certificates and material reports are issued against the order.

DocumentTypeScopeRevisionDateAction
Charge Air Coolers Datasheet2 pages · PDFDatasheetEngine & Generator Cooling · Charge Air CoolersRev. 0401 Oct 2026PDF
Charge Air Coolers — Product Overview4 pages · PDFProduct overviewEngine & Generator Cooling · Charge Air CoolersRev. 0401 Oct 2026PDF
Charge Air Coolers — General Arrangement1 page · PDFDrawingEngine & Generator Cooling · Charge Air CoolersRev. 0301 Oct 2026PDF

Prefer the narrative version? The product overview includes the series ledger, application notes and the document index.

Open product overview

Engine cooling / Charge Air Coolers

Send the duty point. We will return the fit.

The fastest route is a complete duty sheet: media, flow, temperatures, pressure, ambient, plot and documentation requirement. If the duty is still forming, send what you have and we will frame the questions.