NOVARYNINDUSTRIAL LIMITED

Steam condensation / A-frame

Air Cooled Condensers

Air-cooled condenser systems for steam condensation and process services where water consumption, plot plan, and vacuum performance matter.

Family
Heat rejection
Series
3
Core standards
ASME VIII Div. 1 · API 661
Document set
3 records
Air Cooled Condensers — representative Novaryn equipment
Novaryn equipment referenceTX / US

Product overview

Novaryn air-cooled condensers are structured around A-frame, single-row, and tube-system choices. The page emphasizes vacuum support, condensate handling, corrosion protection, and plot restrictions.

Planning reference

Configuration
A-frame and single-row condenser options
Standards
API/ASME-aligned planning path
Duty
Steam condensation without cooling water dependency

Representative summary. Project duty, materials and certification are confirmed at selection.

Specification framework

Standards, materials and the conditions that shape the unit.

The framework below is common to this line. It is not a substitute for a project datasheet: the final pressure class, material schedule, connection detail and test regime are fixed against the duty point.

01

Design standards

  • ASME VIII Div. 1
  • API 661
  • CTI ATC-105
  • PED 2014/68/EU

02

Material scope

  • Hot-dip galvanised steel
  • Stainless steel
  • Aluminium fins
  • CuNi tube
  • C5-M coating

03

Selection inputs

  • Media and flow rate
  • Inlet / outlet temperature
  • Design pressure and temperature
  • Ambient and site conditions
  • Plot, weight and access constraints
  • Documentation and certification

Engineering intent

What this line is built to do.

01

Water-saving condensation

02

Vacuum-aware design

03

Freeze resistance options

04

Code-aligned planning

Areas of application

Typical placements for this line. Final suitability is confirmed against the site conditions and the project specification.

LNGSteel and metallurgyIndustrial cooling processesPulp and paperGas cleaning

Series & variants

3 series. Three planning sizes each.

Series entries define the configuration route. The tables are representative planning grids, not certified performance data. Project-specific ratings, dimensions and connections are issued on the datasheet.

NX-HR-040

MASH

A-frame vacuum condenser

A-frame vacuum condenserSteam duct and manifold designDeflegmation row planning
ModelCapacityFan diameterOperating modePart number
NX-HR-040-S0.5 MW1.5 mAdiabaticNX-HR-040-S
NX-HR-040-M1.0 MW1.8 mEvaporativeNX-HR-040-M
NX-HR-040-L1.5 MW2.1 mDryNX-HR-040-L

NX-HR-041

Single Row

Low steam-side pressure drop

Low steam-side pressure dropFreeze-resistant planningUniform surface use
ModelCapacityFan diameterOperating modePart number
NX-HR-041-S1.0 MW1.8 mEvaporativeNX-HR-041-S
NX-HR-041-M1.5 MW2.1 mDryNX-HR-041-M
NX-HR-041-L2.0 MW2.4 mAdiabaticNX-HR-041-L

NX-HR-042

A-Tube

Corrosion-protected tube platform

Corrosion-protected tube platformHot-dip galvanized transfer pathPressure condenser option
ModelCapacityFan diameterOperating modePart number
NX-HR-042-S1.5 MW2.1 mDryNX-HR-042-S
NX-HR-042-M2.0 MW2.4 mAdiabaticNX-HR-042-M
NX-HR-042-L2.5 MW1.2 mEvaporativeNX-HR-042-L

Representative planning grid · not for construction · certified data on project datasheet

General arrangement

Documentation

The line folder.

Datasheet, product overview and general arrangement are public. Certificates and material reports are issued against the order.

DocumentTypeScopeRevisionDateAction
Air Cooled Condensers Datasheet2 pages · PDFDatasheetHeat Rejection & Heat Recovery · Air Cooled CondensersRev. 0401 Oct 2026PDF
Air Cooled Condensers — Product Overview4 pages · PDFProduct overviewHeat Rejection & Heat Recovery · Air Cooled CondensersRev. 0401 Oct 2026PDF
Air Cooled Condensers — General Arrangement1 page · PDFDrawingHeat Rejection & Heat Recovery · Air Cooled CondensersRev. 0301 Oct 2026PDF

Prefer the narrative version? The product overview includes the series ledger, application notes and the document index.

Open product overview

Heat rejection / Air Cooled Condensers