NOVARYNINDUSTRIAL LIMITED

Immersion cooling / turnkey module

Dielectric Modular Air Cooler

Turnkey dielectric-fluid air coolers for immersion cooling systems and containerized high-density compute environments.

Family
Transformer cooling
Series
1
Core standards
IEC 60076-2 · IEC 60076-7
Document set
3 records
Dielectric Modular Air Cooler — representative Novaryn equipment
Novaryn equipment referenceTX / US

Product overview

Novaryn dielectric modular air coolers combine an aluminum cooler, axial fan, and oil-cooled pump into a portable module that connects to tank-agnostic immersion systems.

Planning reference

Package
Cooler, axial fan, and dielectric pump
Integration
Tank-agnostic connection strategy
Deployment
Containerized or modular systems

Representative summary. Project duty, materials and certification are confirmed at selection.

Specification framework

Standards, materials and the conditions that shape the unit.

The framework below is common to this line. It is not a substitute for a project datasheet: the final pressure class, material schedule, connection detail and test regime are fixed against the duty point.

01

Design standards

  • IEC 60076-2
  • IEC 60076-7
  • IEEE C57.12.00
  • ASME VIII Div. 1

02

Material scope

  • Hot-dip galvanised steel
  • Aluminium
  • Copper
  • Stainless steel
  • C5-M coating

03

Selection inputs

  • Media and flow rate
  • Inlet / outlet temperature
  • Design pressure and temperature
  • Ambient and site conditions
  • Plot, weight and access constraints
  • Documentation and certification

Engineering intent

What this line is built to do.

01

Turnkey package

02

Tank and fluid agnostic route

03

Compact transportable build

04

Maintenance-free oil pump design

Areas of application

Typical placements for this line. Final suitability is confirmed against the site conditions and the project specification.

Blockchain infrastructureHigh-density computeImmersion cooling

Series & variants

1 series. Three planning sizes each.

Series entries define the configuration route. The tables are representative planning grids, not certified performance data. Project-specific ratings, dimensions and connections are issued on the datasheet.

NX-TC-083

Turnkey

Portable dielectric module

Portable dielectric moduleAluminum coolerOil-cooled pump
ModelCooling capacityOil flowMountingPart number
NX-TC-083-S100 kW10 m³/hFree-standingNX-TC-083-S
NX-TC-083-M200 kW20 m³/hRemoteNX-TC-083-M
NX-TC-083-L300 kW30 m³/hTank-mountedNX-TC-083-L

Representative planning grid · not for construction · certified data on project datasheet

General arrangement

Documentation

The line folder.

Datasheet, product overview and general arrangement are public. Certificates and material reports are issued against the order.

DocumentTypeScopeRevisionDateAction
Dielectric Modular Air Cooler Datasheet2 pages · PDFDatasheetTransformer Cooling Systems · Dielectric Modular Air CoolerRev. 0401 Oct 2026PDF
Dielectric Modular Air Cooler — Product Overview4 pages · PDFProduct overviewTransformer Cooling Systems · Dielectric Modular Air CoolerRev. 0401 Oct 2026PDF
Dielectric Modular Air Cooler — General Arrangement1 page · PDFDrawingTransformer Cooling Systems · Dielectric Modular Air CoolerRev. 0301 Oct 2026PDF

Prefer the narrative version? The product overview includes the series ledger, application notes and the document index.

Open product overview

Transformer cooling / Dielectric Modular Air Cooler

Send the duty point. We will return the fit.

The fastest route is a complete duty sheet: media, flow, temperatures, pressure, ambient, plot and documentation requirement. If the duty is still forming, send what you have and we will frame the questions.