NOVARYNINDUSTRIAL LIMITED

Glandless circulation / transformer oil

Oil / Dielectric Pump

Compact oil circulation pumps for forced-oil transformer cooling and dielectric liquid movement.

Family
Transformer cooling
Series
2
Core standards
IEC 60076-2 · IEC 60076-7
Document set
3 records
Oil / Dielectric Pump — representative Novaryn equipment
Novaryn equipment referenceTX / US

Product overview

Novaryn transformer oil pumps are specified for inline, angle-type, radial-impeller, and propeller-type routes depending on transformer class and circuit layout.

Planning reference

Pump type
Inline, angle, radial, or propeller-type
Cooling fluid
Transformer oil or dielectric fluid
Asset type
Power and traction transformer routes

Representative summary. Project duty, materials and certification are confirmed at selection.

Specification framework

Standards, materials and the conditions that shape the unit.

The framework below is common to this line. It is not a substitute for a project datasheet: the final pressure class, material schedule, connection detail and test regime are fixed against the duty point.

01

Design standards

  • IEC 60076-2
  • IEC 60076-7
  • IEEE C57.12.00
  • ASME VIII Div. 1

02

Material scope

  • Hot-dip galvanised steel
  • Aluminium
  • Copper
  • Stainless steel
  • C5-M coating

03

Selection inputs

  • Media and flow rate
  • Inlet / outlet temperature
  • Design pressure and temperature
  • Ambient and site conditions
  • Plot, weight and access constraints
  • Documentation and certification

Engineering intent

What this line is built to do.

01

Simple integration

02

Maintenance-friendly bearing choices

03

Oil-flushed motor and bearings

04

Compact circuit fit

Areas of application

Typical placements for this line. Final suitability is confirmed against the site conditions and the project specification.

Food and meat processingDairyDiesel and electric railMarine on-board systems

Series & variants

2 series. Three planning sizes each.

Series entries define the configuration route. The tables are representative planning grids, not certified performance data. Project-specific ratings, dimensions and connections are issued on the datasheet.

NX-TC-088

Inline

Radial or propeller impeller

Radial or propeller impellerPower transformer applicationsCompact oil circuit
ModelCooling capacityOil flowMountingPart number
NX-TC-088-S100 kW10 m³/hFree-standingNX-TC-088-S
NX-TC-088-M200 kW20 m³/hRemoteNX-TC-088-M
NX-TC-088-L300 kW30 m³/hTank-mountedNX-TC-088-L

NX-TC-089

Traction

Rail transformer pump

Rail transformer pumpRadial impellerVehicle-mounted transformers
ModelCooling capacityOil flowMountingPart number
NX-TC-089-S200 kW20 m³/hRemoteNX-TC-089-S
NX-TC-089-M300 kW30 m³/hTank-mountedNX-TC-089-M
NX-TC-089-L400 kW40 m³/hFree-standingNX-TC-089-L

Representative planning grid · not for construction · certified data on project datasheet

General arrangement

Documentation

The line folder.

Datasheet, product overview and general arrangement are public. Certificates and material reports are issued against the order.

DocumentTypeScopeRevisionDateAction
Oil / Dielectric Pump Datasheet2 pages · PDFDatasheetTransformer Cooling Systems · Oil / Dielectric PumpRev. 0401 Oct 2026PDF
Oil / Dielectric Pump — Product Overview4 pages · PDFProduct overviewTransformer Cooling Systems · Oil / Dielectric PumpRev. 0401 Oct 2026PDF
Oil / Dielectric Pump — General Arrangement1 page · PDFDrawingTransformer Cooling Systems · Oil / Dielectric PumpRev. 0301 Oct 2026PDF

Prefer the narrative version? The product overview includes the series ledger, application notes and the document index.

Open product overview

Transformer cooling / Oil / Dielectric Pump

Send the duty point. We will return the fit.

The fastest route is a complete duty sheet: media, flow, temperatures, pressure, ambient, plot and documentation requirement. If the duty is still forming, send what you have and we will frame the questions.