NOVARYNINDUSTRIAL LIMITED

Gentle cooling / ripening rooms

Draft Free Air Cooler

Low-air-velocity room coolers for produce, cheese, meat, flowers, and sensitive spaces where drafts and noise must stay low.

Family
Evaporators
Series
1
Core standards
ASME B31.5 · EN 378
Document set
3 records
Draft Free Air Cooler — representative Novaryn equipment
Novaryn equipment referenceTX / US

Product overview

Novaryn draft-free units are shaped for even, humid, and quiet cooling. They suit rooms where product maturation, handling comfort, and steady conditions matter more than aggressive air throw.

Planning reference

Capacity class
Low refrigeration loads
Air pattern
Gravity or gentle circulation
Comfort
Low draft and low noise

Representative summary. Project duty, materials and certification are confirmed at selection.

Specification framework

Standards, materials and the conditions that shape the unit.

The framework below is common to this line. It is not a substitute for a project datasheet: the final pressure class, material schedule, connection detail and test regime are fixed against the duty point.

01

Design standards

  • ASME B31.5
  • EN 378
  • CE / PED
  • AHRI 420

02

Material scope

  • Copper tube
  • Aluminium fin
  • Stainless steel
  • Galvanised casing
  • Epoxy-coated coil

03

Selection inputs

  • Media and flow rate
  • Inlet / outlet temperature
  • Design pressure and temperature
  • Ambient and site conditions
  • Plot, weight and access constraints
  • Documentation and certification

Engineering intent

What this line is built to do.

01

Low draft sensation

02

Even room conditions

03

Quiet operation

04

Natural refrigerant readiness

Areas of application

Typical placements for this line. Final suitability is confirmed against the site conditions and the project specification.

DairyBeveragesProcessed foodFood and meat processing

Series & variants

1 series. Three planning sizes each.

Series entries define the configuration route. The tables are representative planning grids, not certified performance data. Project-specific ratings, dimensions and connections are issued on the datasheet.

NX-EV-031

KVB

0.6-4.4 kW class

0.6-4.4 kW classMaturation roomsMoist and even cooling
ModelCapacityAir throwRefrigerantPart number
NX-EV-031-S2.5 kW6 mCO₂NX-EV-031-S
NX-EV-031-M5.0 kW7 mPropane / NH₃NX-EV-031-M
NX-EV-031-L7.5 kW8 mHFC / HFONX-EV-031-L

Representative planning grid · not for construction · certified data on project datasheet

General arrangement

Documentation

The line folder.

Datasheet, product overview and general arrangement are public. Certificates and material reports are issued against the order.

DocumentTypeScopeRevisionDateAction
Draft Free Air Cooler Datasheet2 pages · PDFDatasheetEvaporators · Draft Free Air CoolerRev. 0401 Oct 2026PDF
Draft Free Air Cooler — Product Overview4 pages · PDFProduct overviewEvaporators · Draft Free Air CoolerRev. 0401 Oct 2026PDF
Draft Free Air Cooler — General Arrangement1 page · PDFDrawingEvaporators · Draft Free Air CoolerRev. 0301 Oct 2026PDF

Prefer the narrative version? The product overview includes the series ledger, application notes and the document index.

Open product overview

Evaporators / Draft Free Air Cooler

Send the duty point. We will return the fit.

The fastest route is a complete duty sheet: media, flow, temperatures, pressure, ambient, plot and documentation requirement. If the duty is still forming, send what you have and we will frame the questions.