NOVARYNINDUSTRIAL LIMITED

Evaporative rejection / modular towers

Cooling Towers

Modular and field-erected cooling towers for rejecting industrial, building, power, and data-center heat through evaporative water circuits.

Family
Heat rejection
Series
2
Core standards
ASME VIII Div. 1 · API 661
Document set
3 records
Cooling Towers — representative Novaryn equipment
Novaryn equipment referenceTX / US

Product overview

Novaryn tower systems cover roof-friendly modular installations and large field-erected units. The page focuses on thermal performance, assembly speed, hygienic operation, and maintenance planning.

Planning reference

Capacity class
Modular to 25 MW; field-erected to 100 MW class
Mode
Evaporative water cooling
Planning focus
Assembly, hygiene, noise, and energy

Representative summary. Project duty, materials and certification are confirmed at selection.

Specification framework

Standards, materials and the conditions that shape the unit.

The framework below is common to this line. It is not a substitute for a project datasheet: the final pressure class, material schedule, connection detail and test regime are fixed against the duty point.

01

Design standards

  • ASME VIII Div. 1
  • API 661
  • CTI ATC-105
  • PED 2014/68/EU

02

Material scope

  • Hot-dip galvanised steel
  • Stainless steel
  • Aluminium fins
  • CuNi tube
  • C5-M coating

03

Selection inputs

  • Media and flow rate
  • Inlet / outlet temperature
  • Design pressure and temperature
  • Ambient and site conditions
  • Plot, weight and access constraints
  • Documentation and certification

Engineering intent

What this line is built to do.

01

High capacity per unit

02

Stackable modular options

03

Low-maintenance planning

04

Noise and power tuning

Areas of application

Typical placements for this line. Final suitability is confirmed against the site conditions and the project specification.

District energyAir cooled solutionsSupermarketsHeat rejectionLiquid cooled solutions

Series & variants

2 series. Three planning sizes each.

Series entries define the configuration route. The tables are representative planning grids, not certified performance data. Project-specific ratings, dimensions and connections are issued on the datasheet.

NX-HR-046

Frigate

Up to 25 MW unit class

Up to 25 MW unit classModular and stackableShort on-site assembly
ModelCapacityFan diameterOperating modePart number
NX-HR-046-S0.5 MW1.5 mAdiabaticNX-HR-046-S
NX-HR-046-M1.0 MW1.8 mEvaporativeNX-HR-046-M
NX-HR-046-L1.5 MW2.1 mDryNX-HR-046-L

NX-HR-047

Field

Up to 100 MW unit class

Up to 100 MW unit classLarge manufacturing and energy sitesField-erected tower format
ModelCapacityFan diameterOperating modePart number
NX-HR-047-S1.0 MW1.8 mEvaporativeNX-HR-047-S
NX-HR-047-M1.5 MW2.1 mDryNX-HR-047-M
NX-HR-047-L2.0 MW2.4 mAdiabaticNX-HR-047-L

Representative planning grid · not for construction · certified data on project datasheet

General arrangement

Documentation

The line folder.

Datasheet, product overview and general arrangement are public. Certificates and material reports are issued against the order.

DocumentTypeScopeRevisionDateAction
Cooling Towers Datasheet2 pages · PDFDatasheetHeat Rejection & Heat Recovery · Cooling TowersRev. 0401 Oct 2026PDF
Cooling Towers — Product Overview4 pages · PDFProduct overviewHeat Rejection & Heat Recovery · Cooling TowersRev. 0401 Oct 2026PDF
Cooling Towers — General Arrangement1 page · PDFDrawingHeat Rejection & Heat Recovery · Cooling TowersRev. 0301 Oct 2026PDF

Prefer the narrative version? The product overview includes the series ledger, application notes and the document index.

Open product overview

Heat rejection / Cooling Towers

Send the duty point. We will return the fit.

The fastest route is a complete duty sheet: media, flow, temperatures, pressure, ambient, plot and documentation requirement. If the duty is still forming, send what you have and we will frame the questions.