NOVARYNINDUSTRIAL LIMITED

Horizontal outdoor cooler range

Flatbed Condenser / Drycooler

Flatbed condensers, gas coolers, and drycoolers for outdoor installations that need high power density and flexible configuration.

Family
Heat rejection
Series
4
Core standards
ASME VIII Div. 1 · API 661
Document set
3 records
Flatbed Condenser / Drycooler — representative Novaryn equipment
Novaryn equipment referenceTX / US

Product overview

Novaryn flatbed units suit refrigeration, heat pumps, and industrial outdoor duty. The product page presents drycooler, condenser, gas-cooler, and ammonia-compatible variants in a selection-led layout.

Planning reference

Capacity class
6.4-1424 kW equivalent classes
Equipment types
Drycooler, condenser, gas cooler
Certifications
CE/PED/UL planning path

Representative summary. Project duty, materials and certification are confirmed at selection.

Specification framework

Standards, materials and the conditions that shape the unit.

The framework below is common to this line. It is not a substitute for a project datasheet: the final pressure class, material schedule, connection detail and test regime are fixed against the duty point.

01

Design standards

  • ASME VIII Div. 1
  • API 661
  • CTI ATC-105
  • PED 2014/68/EU

02

Material scope

  • Hot-dip galvanised steel
  • Stainless steel
  • Aluminium fins
  • CuNi tube
  • C5-M coating

03

Selection inputs

  • Media and flow rate
  • Inlet / outlet temperature
  • Design pressure and temperature
  • Ambient and site conditions
  • Plot, weight and access constraints
  • Documentation and certification

Engineering intent

What this line is built to do.

01

High power density

02

Low-noise fan choices

03

Flexible leg arrangements

04

Long coil support

Areas of application

Typical placements for this line. Final suitability is confirmed against the site conditions and the project specification.

Heat pumpsDistrict energyAir cooled solutionsSupermarketsBeverages

Series & variants

4 series. Three planning sizes each.

Series entries define the configuration route. The tables are representative planning grids, not certified performance data. Project-specific ratings, dimensions and connections are issued on the datasheet.

NX-HR-048

LF Drycooler

21-1290 kW class

21-1290 kW classLong coil supportLow-noise controls
ModelCapacityFan diameterOperating modePart number
NX-HR-048-S0.5 MW1.5 mAdiabaticNX-HR-048-S
NX-HR-048-M1.0 MW1.8 mEvaporativeNX-HR-048-M
NX-HR-048-L1.5 MW2.1 mDryNX-HR-048-L

NX-HR-049

LF-S Drycooler

8-125 kW class

8-125 kW classVersatile legsCompact installation
ModelCapacityFan diameterOperating modePart number
NX-HR-049-S1.0 MW1.8 mEvaporativeNX-HR-049-S
NX-HR-049-M1.5 MW2.1 mDryNX-HR-049-M
NX-HR-049-L2.0 MW2.4 mAdiabaticNX-HR-049-L

NX-HR-050

RF/GF-S

6.4-183 kW class

6.4-183 kW classSmall condenser and gas cooler duties
ModelCapacityFan diameterOperating modePart number
NX-HR-050-S1.5 MW2.1 mDryNX-HR-050-S
NX-HR-050-M2.0 MW2.4 mAdiabaticNX-HR-050-M
NX-HR-050-L2.5 MW1.2 mEvaporativeNX-HR-050-L

NX-HR-051

RF/GF/NF

11-1424 kW class

11-1424 kW classLarge condenser, gas cooler, and ammonia duties
ModelCapacityFan diameterOperating modePart number
NX-HR-051-S2.0 MW2.4 mAdiabaticNX-HR-051-S
NX-HR-051-M2.5 MW1.2 mEvaporativeNX-HR-051-M
NX-HR-051-L3.0 MW1.5 mDryNX-HR-051-L

Representative planning grid · not for construction · certified data on project datasheet

General arrangement

Documentation

The line folder.

Datasheet, product overview and general arrangement are public. Certificates and material reports are issued against the order.

DocumentTypeScopeRevisionDateAction
Flatbed Condenser / Drycooler Datasheet2 pages · PDFDatasheetHeat Rejection & Heat Recovery · Flatbed Condenser / DrycoolerRev. 0401 Oct 2026PDF
Flatbed Condenser / Drycooler — Product Overview4 pages · PDFProduct overviewHeat Rejection & Heat Recovery · Flatbed Condenser / DrycoolerRev. 0401 Oct 2026PDF
Flatbed Condenser / Drycooler — General Arrangement1 page · PDFDrawingHeat Rejection & Heat Recovery · Flatbed Condenser / DrycoolerRev. 0301 Oct 2026PDF

Prefer the narrative version? The product overview includes the series ledger, application notes and the document index.

Open product overview

Heat rejection / Flatbed Condenser / Drycooler

Send the duty point. We will return the fit.

The fastest route is a complete duty sheet: media, flow, temperatures, pressure, ambient, plot and documentation requirement. If the duty is still forming, send what you have and we will frame the questions.