NOVARYNINDUSTRIAL LIMITED

High-density V-bank outdoor cooling

V-Shape Condenser / Drycooler

V-bank condensers, gas coolers, and drycoolers for narrow footprints, high capacity density, and outdoor cooling loads.

Family
Heat rejection
Series
4
Core standards
ASME VIII Div. 1 · API 661
Document set
3 records
V-Shape Condenser / Drycooler — representative Novaryn equipment
Novaryn equipment referenceTX / US

Product overview

Novaryn V-shape coolers concentrate capacity into a tighter footprint than horizontal units. They are arranged for warehouses, data centers, indoor climate systems, and refrigeration sites.

Planning reference

Capacity class
6-2805 kW equivalent classes
Geometry
V-bank condenser and drycooler formats
Enhancement
Adiabatic option available

Representative summary. Project duty, materials and certification are confirmed at selection.

Specification framework

Standards, materials and the conditions that shape the unit.

The framework below is common to this line. It is not a substitute for a project datasheet: the final pressure class, material schedule, connection detail and test regime are fixed against the duty point.

01

Design standards

  • ASME VIII Div. 1
  • API 661
  • CTI ATC-105
  • PED 2014/68/EU

02

Material scope

  • Hot-dip galvanised steel
  • Stainless steel
  • Aluminium fins
  • CuNi tube
  • C5-M coating

03

Selection inputs

  • Media and flow rate
  • Inlet / outlet temperature
  • Design pressure and temperature
  • Ambient and site conditions
  • Plot, weight and access constraints
  • Documentation and certification

Engineering intent

What this line is built to do.

01

Small footprint

02

High capacity density

03

Adiabatic option

04

Broad refrigerant coverage

Areas of application

Typical placements for this line. Final suitability is confirmed against the site conditions and the project specification.

Air cooled solutionsSupermarketsBeveragesDairyDistribution centersFood and meat processing

Series & variants

4 series. Three planning sizes each.

Series entries define the configuration route. The tables are representative planning grids, not certified performance data. Project-specific ratings, dimensions and connections are issued on the datasheet.

NX-HR-056

RV/NV/GV T-L

12.5-2805 kW class

12.5-2805 kW classLarge V-bank platformCondenser, ammonia, and gas cooler variants
ModelCapacityFan diameterOperating modePart number
NX-HR-056-S0.5 MW1.5 mAdiabaticNX-HR-056-S
NX-HR-056-M1.0 MW1.8 mEvaporativeNX-HR-056-M
NX-HR-056-L1.5 MW2.1 mDryNX-HR-056-L

NX-HR-057

RV/NV/GV M

7-527 kW class

7-527 kW classMedium V-bank familyCommercial and industrial duty
ModelCapacityFan diameterOperating modePart number
NX-HR-057-S1.0 MW1.8 mEvaporativeNX-HR-057-S
NX-HR-057-M1.5 MW2.1 mDryNX-HR-057-M
NX-HR-057-L2.0 MW2.4 mAdiabaticNX-HR-057-L

NX-HR-058

LV-M Drycooler

6-395 kW class

6-395 kW classSmall footprintAdiabatic option
ModelCapacityFan diameterOperating modePart number
NX-HR-058-S1.5 MW2.1 mDryNX-HR-058-S
NX-HR-058-M2.0 MW2.4 mAdiabaticNX-HR-058-M
NX-HR-058-L2.5 MW1.2 mEvaporativeNX-HR-058-L

NX-HR-059

LV-TL Drycooler

10-2140 kW class

10-2140 kW classHigh-capacity dry coolingV-angle airflow
ModelCapacityFan diameterOperating modePart number
NX-HR-059-S2.0 MW2.4 mAdiabaticNX-HR-059-S
NX-HR-059-M2.5 MW1.2 mEvaporativeNX-HR-059-M
NX-HR-059-L3.0 MW1.5 mDryNX-HR-059-L

Representative planning grid · not for construction · certified data on project datasheet

General arrangement

Documentation

The line folder.

Datasheet, product overview and general arrangement are public. Certificates and material reports are issued against the order.

DocumentTypeScopeRevisionDateAction
V-Shape Condenser / Drycooler Datasheet2 pages · PDFDatasheetHeat Rejection & Heat Recovery · V-Shape Condenser / DrycoolerRev. 0401 Oct 2026PDF
V-Shape Condenser / Drycooler — Product Overview4 pages · PDFProduct overviewHeat Rejection & Heat Recovery · V-Shape Condenser / DrycoolerRev. 0401 Oct 2026PDF
V-Shape Condenser / Drycooler — General Arrangement1 page · PDFDrawingHeat Rejection & Heat Recovery · V-Shape Condenser / DrycoolerRev. 0301 Oct 2026PDF

Prefer the narrative version? The product overview includes the series ledger, application notes and the document index.

Open product overview

Heat rejection / V-Shape Condenser / Drycooler

Send the duty point. We will return the fit.

The fastest route is a complete duty sheet: media, flow, temperatures, pressure, ambient, plot and documentation requirement. If the duty is still forming, send what you have and we will frame the questions.