NOVARYNINDUSTRIAL LIMITED

Extreme pressure / compact bonded core

Diffusion Bonded Heat Exchanger

Diffusion-bonded compact exchangers for extreme pressure and temperature duties including hydrogen and offshore process applications.

Family
Process transfer
Series
2
Core standards
ASME VIII Div. 1 / Div. 2 · TEMA R / C / B
Document set
3 records
Diffusion Bonded Heat Exchanger — representative Novaryn equipment
Novaryn equipment referenceTX / US

Product overview

Novaryn bonded-core exchangers are described for severe services where conventional shell-and-tube size, weight, or approach temperature is not acceptable.

Planning reference

Pressure class
Up to 1050 bar planning class
Temperature class
-200 C to 600 C planning class
Approach
Compact bonded microchannel core

Representative summary. Project duty, materials and certification are confirmed at selection.

Specification framework

Standards, materials and the conditions that shape the unit.

The framework below is common to this line. It is not a substitute for a project datasheet: the final pressure class, material schedule, connection detail and test regime are fixed against the duty point.

01

Design standards

  • ASME VIII Div. 1 / Div. 2
  • TEMA R / C / B
  • API 660
  • API 661

02

Material scope

  • 316L stainless
  • Duplex 2205
  • Titanium
  • Nickel alloys
  • Carbon steel

03

Selection inputs

  • Media and flow rate
  • Inlet / outlet temperature
  • Design pressure and temperature
  • Ambient and site conditions
  • Plot, weight and access constraints
  • Documentation and certification

Engineering intent

What this line is built to do.

01

Very high pressure resistance

02

Cryogenic to high-temperature envelope

03

Small footprint

04

Leak-free core design

Areas of application

Typical placements for this line. Final suitability is confirmed against the site conditions and the project specification.

LNGFSRULNG shipping and terminalsGreen hydrogenGrid

Series & variants

2 series. Three planning sizes each.

Series entries define the configuration route. The tables are representative planning grids, not certified performance data. Project-specific ratings, dimensions and connections are issued on the datasheet.

NX-PT-073

HHX

Hydrogen heavy-duty class

Hydrogen heavy-duty classRefueling station routeExtreme pressure service
ModelSurface areaPressure classMaterialPart number
NX-PT-073-S15 m²PN 25Duplex 2205NX-PT-073-S
NX-PT-073-M30 m²PN 40TitaniumNX-PT-073-M
NX-PT-073-L45 m²PN 100316LNX-PT-073-L

NX-PT-074

SHX

Severe process class

Severe process classOffshore and cryogenic applicationsLow footprint
ModelSurface areaPressure classMaterialPart number
NX-PT-074-S30 m²PN 40TitaniumNX-PT-074-S
NX-PT-074-M45 m²PN 100316LNX-PT-074-M
NX-PT-074-L60 m²PN 16Duplex 2205NX-PT-074-L

Representative planning grid · not for construction · certified data on project datasheet

General arrangement

Documentation

The line folder.

Datasheet, product overview and general arrangement are public. Certificates and material reports are issued against the order.

DocumentTypeScopeRevisionDateAction
Diffusion Bonded Heat Exchanger Datasheet2 pages · PDFDatasheetProcess Heat Transfer · Diffusion Bonded Heat ExchangerRev. 0401 Oct 2026PDF
Diffusion Bonded Heat Exchanger — Product Overview4 pages · PDFProduct overviewProcess Heat Transfer · Diffusion Bonded Heat ExchangerRev. 0401 Oct 2026PDF
Diffusion Bonded Heat Exchanger — General Arrangement1 page · PDFDrawingProcess Heat Transfer · Diffusion Bonded Heat ExchangerRev. 0301 Oct 2026PDF

Prefer the narrative version? The product overview includes the series ledger, application notes and the document index.

Open product overview

Process transfer / Diffusion Bonded Heat Exchanger

Send the duty point. We will return the fit.