NOVARYNINDUSTRIAL LIMITED

Chilled water and glycol air cooling

Cooling Coils

Cooling coils for chilled-water, glycol, and process-air duties where controlled leaving-air conditions and condensate management matter.

Family
Coils
Series
2
Core standards
AHRI 410 · ASME B31.5
Document set
3 records
Cooling Coils — representative Novaryn equipment
Novaryn equipment referenceTX / US

Product overview

Novaryn cooling coils are selected around sensible and latent load, fin spacing, corrosion conditions, drain pan integration, and cleanability. They fit HVAC, production rooms, and industrial air-cooling systems.

Planning reference

Cooling media
Chilled water, glycol, or process fluids
Duty type
Sensible and latent air cooling
Service focus
Drainage, access, and fin cleanability

Representative summary. Project duty, materials and certification are confirmed at selection.

Specification framework

Standards, materials and the conditions that shape the unit.

The framework below is common to this line. It is not a substitute for a project datasheet: the final pressure class, material schedule, connection detail and test regime are fixed against the duty point.

01

Design standards

  • AHRI 410
  • ASME B31.5
  • EN 327
  • PED 2014/68/EU

02

Material scope

  • Copper tube
  • Aluminium fin
  • Stainless steel
  • Cupronickel
  • Galvanised casing

03

Selection inputs

  • Media and flow rate
  • Inlet / outlet temperature
  • Design pressure and temperature
  • Ambient and site conditions
  • Plot, weight and access constraints
  • Documentation and certification

Engineering intent

What this line is built to do.

01

Stable leaving-air control

02

Condensate-aware design

03

Cleanable fin spacing

04

Material options for corrosive air

Areas of application

Typical placements for this line. Final suitability is confirmed against the site conditions and the project specification.

Heat pumpsDistrict energyAir cooled solutionsFood and meat processingPharma

Series & variants

2 series. Three planning sizes each.

Series entries define the configuration route. The tables are representative planning grids, not certified performance data. Project-specific ratings, dimensions and connections are issued on the datasheet.

NX-CL-097

Chilled

Chilled-water cooling

Chilled-water coolingComfort and process airLow pressure drop route
ModelRowsFace areaFin spacingPart number
NX-CL-097-S30.8 m²2.5 mmNX-CL-097-S
NX-CL-097-M41.6 m²3.2 mmNX-CL-097-M
NX-CL-097-L52.4 m²2.1 mmNX-CL-097-L

NX-CL-098

Glycol

Low-temperature glycol coils

Low-temperature glycol coilsFreeze-aware serviceIndustrial process rooms
ModelRowsFace areaFin spacingPart number
NX-CL-098-S41.6 m²3.2 mmNX-CL-098-S
NX-CL-098-M52.4 m²2.1 mmNX-CL-098-M
NX-CL-098-L63.2 m²2.5 mmNX-CL-098-L

Representative planning grid · not for construction · certified data on project datasheet

General arrangement

Documentation

The line folder.

Datasheet, product overview and general arrangement are public. Certificates and material reports are issued against the order.

DocumentTypeScopeRevisionDateAction
Cooling Coils Datasheet2 pages · PDFDatasheetCoils · Cooling CoilsRev. 0401 Oct 2026PDF
Cooling Coils — Product Overview4 pages · PDFProduct overviewCoils · Cooling CoilsRev. 0401 Oct 2026PDF
Cooling Coils — General Arrangement1 page · PDFDrawingCoils · Cooling CoilsRev. 0301 Oct 2026PDF

Prefer the narrative version? The product overview includes the series ledger, application notes and the document index.

Open product overview

Coils / Cooling Coils

Send the duty point. We will return the fit.

The fastest route is a complete duty sheet: media, flow, temperatures, pressure, ambient, plot and documentation requirement. If the duty is still forming, send what you have and we will frame the questions.