NOVARYNINDUSTRIAL LIMITED

Hot water, steam, and thermal oil air heating

Heating Coils

Finned-tube heating coils for air handlers, process make-up air, drying systems, and industrial ventilation units.

Family
Coils
Series
2
Core standards
AHRI 410 · ASME B31.5
Document set
3 records
Heating Coils — representative Novaryn equipment
Novaryn equipment referenceTX / US

Product overview

Novaryn heating coils are configured around air volume, entering temperature, heating medium, freeze risk, casing limits, and service access. They support hot water, steam, glycol, and thermal oil applications.

Planning reference

Heating media
Hot water, steam, glycol, or thermal oil
Tube options
Copper, stainless, or specialist materials
Design focus
Airflow, pressure drop, and leaving-air temperature

Representative summary. Project duty, materials and certification are confirmed at selection.

Specification framework

Standards, materials and the conditions that shape the unit.

The framework below is common to this line. It is not a substitute for a project datasheet: the final pressure class, material schedule, connection detail and test regime are fixed against the duty point.

01

Design standards

  • AHRI 410
  • ASME B31.5
  • EN 327
  • PED 2014/68/EU

02

Material scope

  • Copper tube
  • Aluminium fin
  • Stainless steel
  • Cupronickel
  • Galvanised casing

03

Selection inputs

  • Media and flow rate
  • Inlet / outlet temperature
  • Design pressure and temperature
  • Ambient and site conditions
  • Plot, weight and access constraints
  • Documentation and certification

Engineering intent

What this line is built to do.

01

Medium-flexible design

02

Low air-side pressure drop

03

Header and circuit customization

04

Freeze-protection planning

Areas of application

Typical placements for this line. Final suitability is confirmed against the site conditions and the project specification.

Heat pumpsDistrict energyFood and meat processingPulp and paperWaste-to-energy

Series & variants

2 series. Three planning sizes each.

Series entries define the configuration route. The tables are representative planning grids, not certified performance data. Project-specific ratings, dimensions and connections are issued on the datasheet.

NX-CL-101

Water

Hot water and glycol coils

Hot water and glycol coilsAir handling unitsDistrict energy tie-ins
ModelRowsFace areaFin spacingPart number
NX-CL-101-S30.8 m²2.5 mmNX-CL-101-S
NX-CL-101-M41.6 m²3.2 mmNX-CL-101-M
NX-CL-101-L52.4 m²2.1 mmNX-CL-101-L

NX-CL-102

Steam

Steam heating coils

Steam heating coilsProcess make-up airCondensate-aware circuiting
ModelRowsFace areaFin spacingPart number
NX-CL-102-S41.6 m²3.2 mmNX-CL-102-S
NX-CL-102-M52.4 m²2.1 mmNX-CL-102-M
NX-CL-102-L63.2 m²2.5 mmNX-CL-102-L

Representative planning grid · not for construction · certified data on project datasheet

General arrangement

Documentation

The line folder.

Datasheet, product overview and general arrangement are public. Certificates and material reports are issued against the order.

DocumentTypeScopeRevisionDateAction
Heating Coils Datasheet2 pages · PDFDatasheetCoils · Heating CoilsRev. 0401 Oct 2026PDF
Heating Coils — Product Overview4 pages · PDFProduct overviewCoils · Heating CoilsRev. 0401 Oct 2026PDF
Heating Coils — General Arrangement1 page · PDFDrawingCoils · Heating CoilsRev. 0301 Oct 2026PDF

Prefer the narrative version? The product overview includes the series ledger, application notes and the document index.

Open product overview

Coils / Heating Coils

Send the duty point. We will return the fit.

The fastest route is a complete duty sheet: media, flow, temperatures, pressure, ambient, plot and documentation requirement. If the duty is still forming, send what you have and we will frame the questions.