NOVARYNINDUSTRIAL LIMITED

Retrofit coils / measured-to-fit replacement

Replacement Coil Blocks

Replacement coil blocks for refurbishing air handlers, condensers, drycoolers, evaporators, and process air equipment without replacing the full unit.

Family
Coils
Series
2
Core standards
AHRI 410 · ASME B31.5
Document set
3 records
Replacement Coil Blocks — representative Novaryn equipment
Novaryn equipment referenceTX / US

Product overview

Novaryn replacement coil blocks are built from site measurements, duty requirements, material preferences, and access constraints. They are useful where existing casing, fans, controls, or structure can remain in service.

Planning reference

Scope
Coil-only replacement or upgraded coil block
Inputs
Existing dimensions, duty data, fluids, and connection details
Outcome
Thermal restoration without full equipment replacement

Representative summary. Project duty, materials and certification are confirmed at selection.

Specification framework

Standards, materials and the conditions that shape the unit.

The framework below is common to this line. It is not a substitute for a project datasheet: the final pressure class, material schedule, connection detail and test regime are fixed against the duty point.

01

Design standards

  • AHRI 410
  • ASME B31.5
  • EN 327
  • PED 2014/68/EU

02

Material scope

  • Copper tube
  • Aluminium fin
  • Stainless steel
  • Cupronickel
  • Galvanised casing

03

Selection inputs

  • Media and flow rate
  • Inlet / outlet temperature
  • Design pressure and temperature
  • Ambient and site conditions
  • Plot, weight and access constraints
  • Documentation and certification

Engineering intent

What this line is built to do.

01

Keeps usable equipment in service

02

Measured-to-fit geometry

03

Material upgrade path

04

Reduced shutdown scope

Areas of application

Typical placements for this line. Final suitability is confirmed against the site conditions and the project specification.

Air cooled solutionsHeat rejectionDistrict energyPulp and paperIndustrial cooling processes

Series & variants

2 series. Three planning sizes each.

Series entries define the configuration route. The tables are representative planning grids, not certified performance data. Project-specific ratings, dimensions and connections are issued on the datasheet.

NX-CL-107

LikeForLike

Direct replacement coil

Direct replacement coilMeasured-to-fitFast retrofit path
ModelRowsFace areaFin spacingPart number
NX-CL-107-S30.8 m²2.5 mmNX-CL-107-S
NX-CL-107-M41.6 m²3.2 mmNX-CL-107-M
NX-CL-107-L52.4 m²2.1 mmNX-CL-107-L

NX-CL-108

Upgrade

Material or performance upgrade

Material or performance upgradeCorrosion and capacity improvementsLife-extension projects
ModelRowsFace areaFin spacingPart number
NX-CL-108-S41.6 m²3.2 mmNX-CL-108-S
NX-CL-108-M52.4 m²2.1 mmNX-CL-108-M
NX-CL-108-L63.2 m²2.5 mmNX-CL-108-L

Representative planning grid · not for construction · certified data on project datasheet

General arrangement

Documentation

The line folder.

Datasheet, product overview and general arrangement are public. Certificates and material reports are issued against the order.

DocumentTypeScopeRevisionDateAction
Replacement Coil Blocks Datasheet2 pages · PDFDatasheetCoils · Replacement Coil BlocksRev. 0401 Oct 2026PDF
Replacement Coil Blocks — Product Overview4 pages · PDFProduct overviewCoils · Replacement Coil BlocksRev. 0401 Oct 2026PDF
Replacement Coil Blocks — General Arrangement1 page · PDFDrawingCoils · Replacement Coil BlocksRev. 0301 Oct 2026PDF

Prefer the narrative version? The product overview includes the series ledger, application notes and the document index.

Open product overview

Coils / Replacement Coil Blocks

Send the duty point. We will return the fit.

The fastest route is a complete duty sheet: media, flow, temperatures, pressure, ambient, plot and documentation requirement. If the duty is still forming, send what you have and we will frame the questions.