NX-PHE-001
Watersafe
16 bar class
| Model | Plate area | Connection | Pressure class | Part number |
|---|---|---|---|---|
| NX-PHE-001-S | 18 m² | DN 80 | PN 25 | NX-PHE-001-S |
| NX-PHE-001-M | 36 m² | DN 100 | PN 40 | NX-PHE-001-M |
| NX-PHE-001-L | 54 m² | DN 150 | PN 16 | NX-PHE-001-L |
Thermal equipment · Houston, USA · Since 2009
Compact sealed plate packs
Factory-brazed exchangers for high efficiency in compact spaces, prepared for water, refrigerant, and utility-loop duties.

Product overview
Novaryn brazed plate units are positioned for fast equipment selection where footprint, weight, and thermal approach matter. The range covers potable-water separation, refrigeration, heat pumps, high-pressure refrigerants, and corrosion-sensitive duties through material and circuit variations.
Planning reference
Representative summary. Project duty, materials and certification are confirmed at selection.
Specification framework
The framework below is common to this line. It is not a substitute for a project datasheet: the final pressure class, material schedule, connection detail and test regime are fixed against the duty point.
01
02
03
Engineering intent
Small installed footprint
Low hold-up volume
High turbulence transfer
Multiple pressure classes
Areas of application
Typical placements for this line. Final suitability is confirmed against the site conditions and the project specification.
Series & variants
Series entries define the configuration route. The tables are representative planning grids, not certified performance data. Project-specific ratings, dimensions and connections are issued on the datasheet.
NX-PHE-001
16 bar class
| Model | Plate area | Connection | Pressure class | Part number |
|---|---|---|---|---|
| NX-PHE-001-S | 18 m² | DN 80 | PN 25 | NX-PHE-001-S |
| NX-PHE-001-M | 36 m² | DN 100 | PN 40 | NX-PHE-001-M |
| NX-PHE-001-L | 54 m² | DN 150 | PN 16 | NX-PHE-001-L |
NX-PHE-002
35-45 bar class
| Model | Plate area | Connection | Pressure class | Part number |
|---|---|---|---|---|
| NX-PHE-002-S | 36 m² | DN 100 | PN 40 | NX-PHE-002-S |
| NX-PHE-002-M | 54 m² | DN 150 | PN 16 | NX-PHE-002-M |
| NX-PHE-002-L | 72 m² | DN 50 | PN 16 | NX-PHE-002-L |
NX-PHE-003
46-140 bar class
| Model | Plate area | Connection | Pressure class | Part number |
|---|---|---|---|---|
| NX-PHE-003-S | 54 m² | DN 150 | PN 16 | NX-PHE-003-S |
| NX-PHE-003-M | 72 m² | DN 50 | PN 16 | NX-PHE-003-M |
| NX-PHE-003-L | 90 m² | DN 80 | PN 25 | NX-PHE-003-L |
NX-PHE-004
Safety separation
| Model | Plate area | Connection | Pressure class | Part number |
|---|---|---|---|---|
| NX-PHE-004-S | 72 m² | DN 50 | PN 16 | NX-PHE-004-S |
| NX-PHE-004-M | 90 m² | DN 80 | PN 25 | NX-PHE-004-M |
| NX-PHE-004-L | 108 m² | DN 100 | PN 40 | NX-PHE-004-L |
NX-PHE-005
Corrosion-sensitive duties
| Model | Plate area | Connection | Pressure class | Part number |
|---|---|---|---|---|
| NX-PHE-005-S | 90 m² | DN 80 | PN 25 | NX-PHE-005-S |
| NX-PHE-005-M | 108 m² | DN 100 | PN 40 | NX-PHE-005-M |
| NX-PHE-005-L | 126 m² | DN 150 | PN 16 | NX-PHE-005-L |
Representative planning grid · not for construction · certified data on project datasheet
General arrangementDocumentation
Datasheet, product overview and general arrangement are public. Certificates and material reports are issued against the order.
| Document | Type | Scope | Revision | Date | Action |
|---|---|---|---|---|---|
| Brazed Plate Heat Exchangers Datasheet2 pages · PDF | Datasheet | Plate Heat Exchangers · Brazed Plate Heat Exchangers | Rev. 04 | 01 Oct 2026 | |
| Brazed Plate Heat Exchangers — Product Overview4 pages · PDF | Product overview | Plate Heat Exchangers · Brazed Plate Heat Exchangers | Rev. 04 | 01 Oct 2026 | |
| Brazed Plate Heat Exchangers — General Arrangement1 page · PDF | Drawing | Plate Heat Exchangers · Brazed Plate Heat Exchangers | Rev. 03 | 01 Oct 2026 |
Prefer the narrative version? The product overview includes the series ledger, application notes and the document index.
Open product overviewPlate exchangers / Brazed Plate Heat Exchangers
The fastest route is a complete duty sheet: media, flow, temperatures, pressure, ambient, plot and documentation requirement. If the duty is still forming, send what you have and we will frame the questions.