NOVARYNINDUSTRIAL LIMITED

Openable frames / flexible capacity

Gasketed Plate Heat Exchangers

Serviceable framed plate exchangers for processes that need inspection access, capacity adjustment, and broad material compatibility.

Family
Plate exchangers
Series
6
Core standards
ASME VIII Div. 1 · PED 2014/68/EU
Document set
3 records
Gasketed Plate Heat Exchangers — representative Novaryn equipment
Novaryn equipment referenceTX / US

Product overview

Novaryn gasketed units are designed as modular thermal frames. The page covers high-flow utility systems, hygienic process fluids, particle-bearing media, double-wall separation, and semi-welded cassette options for more demanding refrigerants or process fluids.

Planning reference

Frame model
Openable bolted frame
Design emphasis
Service access and thermal flexibility
Media options
Clean, viscous, sensitive, and particle-bearing fluids

Representative summary. Project duty, materials and certification are confirmed at selection.

Specification framework

Standards, materials and the conditions that shape the unit.

The framework below is common to this line. It is not a substitute for a project datasheet: the final pressure class, material schedule, connection detail and test regime are fixed against the duty point.

01

Design standards

  • ASME VIII Div. 1
  • PED 2014/68/EU
  • AHRI 400

02

Material scope

  • 316L stainless
  • 304 stainless
  • Titanium
  • SMO 254
  • NBR / EPDM / HNBR gaskets

03

Selection inputs

  • Media and flow rate
  • Inlet / outlet temperature
  • Design pressure and temperature
  • Ambient and site conditions
  • Plot, weight and access constraints
  • Documentation and certification

Engineering intent

What this line is built to do.

01

Expandable plate pack

02

Accessible cleaning

03

Broad gasket options

04

Low approach temperatures

Areas of application

Typical placements for this line. Final suitability is confirmed against the site conditions and the project specification.

BeveragesDairyDistribution centersGridProcessed foodHeat rejection

Series & variants

6 series. Three planning sizes each.

Series entries define the configuration route. The tables are representative planning grids, not certified performance data. Project-specific ratings, dimensions and connections are issued on the datasheet.

NX-PHE-008

HeatPump HP

High-pressure semi-welded

High-pressure semi-weldedCommercial heat pumpsCritical media channel
ModelPlate areaConnectionPressure classPart number
NX-PHE-008-S18 m²DN 80PN 25NX-PHE-008-S
NX-PHE-008-M36 m²DN 100PN 40NX-PHE-008-M
NX-PHE-008-L54 m²DN 150PN 16NX-PHE-008-L

NX-PHE-009

Universal

DN25-DN500 connections

DN25-DN500 connectionsBroad flow rangeMultiple plate materials
ModelPlate areaConnectionPressure classPart number
NX-PHE-009-S36 m²DN 100PN 40NX-PHE-009-S
NX-PHE-009-M54 m²DN 150PN 16NX-PHE-009-M
NX-PHE-009-L72 m²DN 50PN 16NX-PHE-009-L

NX-PHE-010

District

High NTU duties

High NTU dutiesLow temperature differencesData center loops
ModelPlate areaConnectionPressure classPart number
NX-PHE-010-S54 m²DN 150PN 16NX-PHE-010-S
NX-PHE-010-M72 m²DN 50PN 16NX-PHE-010-M
NX-PHE-010-L90 m²DN 80PN 25NX-PHE-010-L

NX-PHE-011

WideGap

Viscous and solids-bearing media

Viscous and solids-bearing mediaLarger flow channelReduced clogging tendency
ModelPlate areaConnectionPressure classPart number
NX-PHE-011-S72 m²DN 50PN 16NX-PHE-011-S
NX-PHE-011-M90 m²DN 80PN 25NX-PHE-011-M
NX-PHE-011-L108 m²DN 100PN 40NX-PHE-011-L

NX-PHE-012

FreeFlow

Fiber and solids handling

Fiber and solids handlingWastewater, sugar, and paper style duties
ModelPlate areaConnectionPressure classPart number
NX-PHE-012-S90 m²DN 80PN 25NX-PHE-012-S
NX-PHE-012-M108 m²DN 100PN 40NX-PHE-012-M
NX-PHE-012-L126 m²DN 150PN 16NX-PHE-012-L

NX-PHE-013

DoubleWall

Safety separation

Safety separationPotable water and incompatible-media duties
ModelPlate areaConnectionPressure classPart number
NX-PHE-013-S108 m²DN 100PN 40NX-PHE-013-S
NX-PHE-013-M126 m²DN 150PN 16NX-PHE-013-M
NX-PHE-013-L144 m²DN 50PN 16NX-PHE-013-L

Representative planning grid · not for construction · certified data on project datasheet

General arrangement

Documentation

The line folder.

Datasheet, product overview and general arrangement are public. Certificates and material reports are issued against the order.

DocumentTypeScopeRevisionDateAction
Gasketed Plate Heat Exchangers Datasheet2 pages · PDFDatasheetPlate Heat Exchangers · Gasketed Plate Heat ExchangersRev. 0401 Oct 2026PDF
Gasketed Plate Heat Exchangers — Product Overview4 pages · PDFProduct overviewPlate Heat Exchangers · Gasketed Plate Heat ExchangersRev. 0401 Oct 2026PDF
Gasketed Plate Heat Exchangers — General Arrangement1 page · PDFDrawingPlate Heat Exchangers · Gasketed Plate Heat ExchangersRev. 0301 Oct 2026PDF

Prefer the narrative version? The product overview includes the series ledger, application notes and the document index.

Open product overview

Plate exchangers / Gasketed Plate Heat Exchangers

Send the duty point. We will return the fit.

The fastest route is a complete duty sheet: media, flow, temperatures, pressure, ambient, plot and documentation requirement. If the duty is still forming, send what you have and we will frame the questions.